Requirements
- 2 PC's to which Ronja can be connected
- Full duplex AUI network cards or Half Duplex Reduction(s)
- Access to one of the PC's or 3rd PC connected to one side of the link by
full-duplex wired or fiber optic network.
|
|
|
|
Connecting just electronics
If you are testing just bare electronics on the floor,
connect the components according to the picture.
|
|
|
|
Running ping
- You can select payload length in ping. The flag for this selection varies
depending on ping vendor. Select suitable one to get packetloss between 0%
and 100%. 56 bytes are default. Use max. 1472.
- If you have neither scientific calculator, nor access to www nor local running copy of Ronja web,
then select only 14, 56, or 1472 bytes of ping payload
- If the ping allows you to specify -c to send packet as soon as the
previous one arrives, use this flag.
- If you are using the -c flag, then run two instances of the
ping at the same time (in different xterm windows or consoles).
- Do not use the -f (flood ping) option. This would render the
measured BER invalid.
- Leave the ping to run long enough to have multiple dropped packets.
The longer the better precision.
- Press ctrl-c and read out the packetloss (in %)
|
|